9/16
4. Troubleshooting
45900
45900
Error message: F replenishment
No. 05912[F]
Predetermined process amount was exceeded.
Error message release
YES
Condition
Condition
When an error in the following error list occurred and printing was performed before the error was cleared, the integrated value of P1R
replenishment amount exceeded the specified amount.
• Specified amount for the QSS-3701/3702/3703/LP7500/LP7600: about 507 prints (127 mm × 89 mm size)
• Specified amount for the QSS-3704/3705/LP7700/LP7900: about 545 prints (127 mm × 89 mm size)
Take the corrective action in the error list.
Error list Countermeasure
• ☞No. 00902[F] • Install the replenisher cartridge. Perform recovery procedure 3 from
the replenishment error.
☞4621
•
☞No. 00905[F] • Install the new replenisher cartridge.
•
☞No. 05900[F] • Replenisher cartridge open motor operation error. Recovery procedure from the
error(s) shown in the left
•
☞No. 05905[F]
•
☞No. 05906[F]
• ☞No. 05907[F]
• P1R replenishment solution output amount/replenishment solution
level management is abnormal.
• P2RA replenishment solution output amount/replenishment
solution level management is abnormal.
• P2RA replenishment solution output amount/replenishment
solution level management is abnormal.
Recovery procedure from the
error(s) shown in the left
•
☞No. 05908[F] • Failed to open the replenisher cartridge. Recovery procedure from the
error(s) shown in the left
•
☞No. 05909[F]
• ☞No. 05910[F]
•
☞No. 05911[F]
• Cartridge cleaning valve/Agitation solenoid valve is abnormal.
P1R
• Cartridge cleaning valve cleaning valve is abnormal. P2RA
• Cartridge cleaning valve cleaning valve is abnormal. P2RB
Recovery procedure from the
error(s) shown in the left
•
☞No. 05913[F] • An error occurred in the replenisher section. Recovery procedure from the
error(s) shown in the left
•
☞No. 05923[F] • Solution remains in the replenishment tank. Perform recovery procedure 3 from
the replenishment error.
☞4621
• Even if an error is cleared, it reoccurs until the replenisher cartridge is opened (replenishment solution is created).
Countermeasure
1. See the Error Record, and check which error occurred.
NOTE
• Attentions such as ☞No. 00902[F] or ☞No. 00905[F] are not shown on the Error Record.
If the EZ Controller is used
Bringing up the display
Controller Main Display: 2260 → Click F. → Management Tool → System management → Error Record
2. Perform the recovery procedure from the error.
Distributed by: minilablaser.com