4. Troubleshooting
46000
46000
Error message: Printer 1
No. 06081
Backup data error. Printer
IMPORTANT
If the error message above appears, it cannot be closed for approx. 5 to 10 minutes until the Maintenance Display is
shown.
Error message release
NO
Condition
NOTE
The value informed from CPU is displayed in the last three digits of the suffix number.
If about 5 days has passed with the power supply off or if the printer control PCB is replaced with a new one, this error message will
be shown.
IMPORTANT
If the error message above appears, the backup data for the printer control PCB saved in printer I/F main PCB is sent to
the printer control PCB within approx. 5 to 10 minutes while the error cannot be canceled.
If the backup data is sent normally, the error above can be closed.
However, the backup data saved in the printer I/F main PCB may have a problem. If the error above occurs, we
recommend you to read the backup data on the media saved at the close down check.
Diagnosis
NOTE
To access the wiring diagrams, click Wiring diagrams in Bookmarks.
Suffix number Condition
0###H The backup data of the printer control PCB is abnormal.
The new printer control PCB is attached.
The RAM of printer control PCB is broken.
The power supply of backup for printer control PCB is shut off.
1###H The backup data of the printer control PCB is abnormal.
Backup data of the printer I/F main PCB does not exist.
If the data was deleted Manual No.
Read the backup data saved in media at the close down check.
35400
Failed part Manual No.
Printer control PCB
66000
Printer I/F main PCB
66005