5. Operation sequence
55530
55530
Paper advance operation
5. Arm units 2 (right) (left) move to the processor loading unit.
• Paper advance arm motors (right) (left): ON/OFF
If the arm sensors (right) (left) do not turn light
• ☞ No. 06138-00002
Paper Advance Arm Motor (Left) operation error.
•
☞No. 06139-00002
Paper Advance Arm Motor (Right) operation error.
6. Arm units 2 (right, left) release the pressure.
• Paper advance pressure change motors (right) (left): ON (released)/OFF
If the paper advance pressure change sensors (right) (left) do not turn LIGHT
• ☞ No. 06142-00002
Paper Advance Pressure Change Motor (Left) operation error.
•
☞No. 06143-00002
Paper Advance Pressure Change Motor (Right) operation error.
G069959