Upgrade and Maintenance Manual 141
Hard disk drives / solid state drives
V CAUTION!
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators on the HDD
module, as described in the operating manual of your server.
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.3.4.1 Preliminary steps
Ê "Locating the defective server" on page 49
Ê Locate the defective HDD module as described in section "Local diagnostic
indicators on the front" on page 51.
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide and manuals of RAID controller.
7.3.4.2 Removing a 3.5-inch HDD module
Ê "Removing a 3.5-inch HDD module" on page 139
7.3.4.3 Installing a 3.5-inch HDD module
Ê "Installing 3.5-inch HDD modules" on page 136
7.3.4.4 Concluding steps
Ê "Performing a RAID array rebuild" on page 94