15.3.2.10 Steps
Ê "Disabling or suspending BitLocker functionality" on page 67
Ê "Shutting down the server" on page 51
Ê "Disconnecting power cords" on page 52
Ê Remove all external cables.
Ê "Getting access to the component" on page 53
Ê "Removing the fan box" on page 168
Ê "Removing the front cover" on page 376
Ê Remove the HDD modules and HDD dummy modules, see "Removing a
3.5-inch HDD module" on page 141 and "Removing a 2.5-inch dummy
module" on page 128.
Ê Remove the HDD cage 1, see "Removing a HDD cage" on page 158
Ê Remove the 4x2.5-inch HDD backplanes from cage 2 and 3, see "Removing
the 4x 2.5-inch SAS HDD backplane" on page 143
Ê Install the HDD cage 1 "Installing a HDD cage" on page 159
Ê "Installing the 12x 2.5-inch HDD SAS backplane" on page 148
Ê Installing the HDD modules or HDD dummy modules, see "Installing a 2.5-
inch HDD / SSD module" on page 129 and "Installing a 2.5-inch dummy
module" on page 132.
Ê "Installing the front cover 2.5-inch version" on page 377
Ê For more information about the cabling, see "Configuration 7" on page 407.
Ê "Installing the fan box" on page 171
Ê "Reassembling" on page 59
Ê Connect all external cables.
Ê "Connecting the server to the power source" on page 64
Ê Update your server’s chassis information on the Chassis ID EPROM
integrated into the front panel board. For further information on how to obtain
and use the ChassisId_Prom Tool, refer to section "Using the Chassis ID
Prom Tool" on page 97.
Ê "Enabling BitLocker functionality" on page 93