EasyManua.ls Logo

Fujitsu PRIMERGY RX2520 M1 - Server Configuration Guide

Fujitsu PRIMERGY RX2520 M1
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78 Upgrade and Maintenance Manual
RX2520 M1
Basic software procedures
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section "Viewing and clearing the System Event Log (SEL)" on
page 90).
After replacing the system board
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 90 to verify whether the backup data on
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Restore successful
After replacing the Chassis ID EPROM
I In case of the PRIMERGY RX2520 M1 server, the Chassis ID EPROM
is integrated on the front panel board.
Ê Check the SEL log files as described in section "Viewing and clearing the
System Event Log (SEL)" on page 90 to verify whether a backup copy of the
system board settings has been transferred to the Chassis ID EPROM:
Chassis IDPROM: Backup successful

Table of Contents

Other manuals for Fujitsu PRIMERGY RX2520 M1

Related product manuals