BGS2T AT Command Set
5.4 AT+CLCK
BGS2T_ATC_V01.301 Page 122 of 554 1/31/12
c
ation not supported" etc.). To make sure check the extended error response with AT+CEER and the lock status
with <mode>=2.
<password>: Network password supplied from the provider or operator. Usually there is one password which
applies to all call barring options. For details contact your provider.
“AO“ BAOC (Bar All Outgoing Calls)
“OI“ BOIC (Bar Outgoing International Calls)
“OX“ BOIC-exHC (Bar Outgoing International Calls except to Home Country)
“AI“ BAIC (Bar All Incoming Calls)
“IR“ BIC-Roam (Bar Incoming Calls when Roaming outside the home country)
“AB“ All Barring services (applicable only for <mode>=0)
“AG“ All outGoing barring services (applicable only for <mode>=0)
“AC“ All inComing barring services (applicable only for <mode>=0)
0Unlock
1Lock
2 Query status
0 Lock is inactive
1 Lock is active
Password string used to lock and to unlock a <facility>. Length and authority for passwords depend on the
<facility> in question and are therefore listed in the section on parameter <facility>. Passwords can be
modified with AT+CPWD or AT^SPWD.
Integer or sum of integers each representing a class of information, i.e. a bearer service, telecommunication ser-
vice or bearer service group as defined in 3GPP TS 22.004 [17].
1Voice
2 Class 2 ("data") comprises all those individual data classes between 16 and
128, that are supported both by the network and the MS. This means, a setting
made for class 2 applies to all individual data classes (if supported). In addition,
you can assign a different setting to a specific class. For example, you can acti-
vate Call Forwarding for all data classes, but deactivate it for data class 64,
"dedicated packet access".
4Fax
8SMS
16 Data circuit sync
32 Data circuit async
64 Dedicated packet access
128 Dedicated PAD access
1...[7]...255 Combination of some of the above classes.
For example, the default setting 7 represents the sum of the integers 1, 2 and
4 (voice, data and fax).
The value 255 covers all classes.
If parameter "class" is omitted, the default value 7 is used.
<mode>
(num)
<status>
(num)
<password>
(str)
<class>
(num)
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals