BGS2T AT Command Set
5.6 AT+CPWD
BGS2T_ATC_V01.301 Page 128 of 554 1/31/12
c
“IR“ BIC-Roam (Bar Incoming Calls when Roaming outside the home country)
“AB“ All Barring services
“AG“ All outGoing barring services
“AC“ All inComing barring services
4...8 Length of password. The range of permitted length for a password depends on
the associated <facility>. It is available from the test command response,
or in the description of parameter <facility>.
Password specified for the facility.
Parameter <old password> can be ignored if no old password was allocated to the facility.
Take into account that a password may have already been set by factory, or that the service is subject to a pass-
word issued by the provider. See notes above or contact provider.
New password. Mandatory, if <old password> was an unblocking key (such as the Master Phone Code).
Note
• When changing PIN2 (<facility>="P2") it is recommended to check the new state of PIN2 by using the
AT+CPIN2 command.
Examples
EXAMPLE 1
To change PIN2
EXAMPLE 2
To set password used to enable or disable barring of all outgoing calls:
EXAMPLE 3
Handling of the "PS" lock password
EXAMPLE 4
To specify a new "PS" lock password, after the old password was disabled (e.g. after three failed attempts to
change the "PS" password): use the master phone code.
<password length>
(num)
<old password>
(str)
<new password>
(str)
AT+CPWD="P2","0000","8888"
(where "0000" = old PIN2 and "8888" = new PIN2)
OK
PIN2 Password has been changed to "8888"
AT+CPWD="AO","0000","3333"
Requests the network to change the password for
supplementary service "call barring".
OK
Usually this request will affect all barring services,
even though the request is issued for Supplementary
Service BAOC ("Barring of all outgoing calls") only.
Refer to the respective network provider for detail.
AT+CMEE=2
Enable text output of CME Error information
AT+CPWD="PS","1111","2222"
(where "1111" = old password and "2222" = new
password)
OK
Password for facility "PS" is now "2222"
AT+CPWD="PS","1111","2222"
Repeat command to provoke error "incorrect pass-
word"
+CME ERROR: incorrect password
("1111" is no longer the correct password)
Confidential / Released

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto CINTERION BGS2T and is the answer not in the manual?

Gemalto CINTERION BGS2T Specifications

General IconGeneral
BrandGemalto
ModelCINTERION BGS2T
CategoryTouch terminals
LanguageEnglish

Related product manuals