EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
4. Check the Light path diagnostics LEDs for the correct combination of power
LEDs that should be displayed during typical operation.
Light path diagnostics LEDs
LEDs on the light path diagnostics panel of the file module indicate the cause of a
problem. The topic describes the suggested actions to correct the detected
problems.
Table 43. LED indicators, corresponding problem causes, and corrective actions
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)," that step must be completed only by a trained
technician.
LED Problem Action
Check log LED An error occurred and cannot be
isolated without completing
certain procedures.
1. Check the IMM2 system event log and the system-error
log for information about the error.
2. Save the log if necessary and clear the log afterward.
System-error
LED
An error occurred.
1. Check the light path diagnostics LEDs and follow the
instructions.
2. Check the IMM2 system event log and the system-error
log for information about the error.
3. Save the log if necessary and clear the log afterward.
PS When only the PS LED is lit, a
power supply has failed.
The system might detect a power supply error. Complete the
following steps to correct the problem:
1. Check the power-supply with a lit yellow LED.
2. Make sure that the power supplies are seated correctly
and plugged in a good AC outlet.
3. Remove one of the power supplies to isolate the failed
power supply.
4. Make sure that both power supplies installed in the file
module are of the same AC input voltage.
5. Replace the failed power supply.
PS + CONFIG
When both the PS and CONFIG
LEDs are lit, the power supply
configuration is invalid.
If the PS LED and the CONFIG LED are lit, the system issues
an invalid power configuration error. Make sure that both
power supplies installed in the file module are of the same
rating or wattage.
OVER SPEC The system consumption reaches
the power supply over current
protection point or the power
supplies are damaged.
1. If the Power Rail (A, B, C, D, E, F, G, and H) error was
not detected, complete the following steps:
a. Use the IBM Power Configurator utility to determine
current system power consumption. For more
information and to download the utility, go to
http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
b. Replace the failed power supply.
2. If the Power Rail (A, B, C, D, E, F, G, and H) error was
also detected, follow actions in the "Power problems"
under the Troubleshooting tables and "Solving power
problems" in the Problem Determination and Service Guide.
80 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI