EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
Chapter 4. File module
This topic provides information about troubleshooting the file module, which
includes error codes, problem scenarios, software troubleshooting, and removal
and replacement instructions.
General file module procedures
This section covers file module general maintenance and repair issues.
Rebooting a file module
Use this procedure to initiate a file module reboot.
Before you begin
Events can occur on a file module that require the hardware to be rebooted.
Procedure
1. To shut down and restart a node by using the management GUI, follow these
steps:
a. Click Monitoring > System Details.
b. Click the Interface Nodes tab.
c. In the left pane, select the node to reboot. In the right pane, click Actions >
Restart.
Note: If the file module to be rebooted is the active management node, the
management GUI will also shut down and cause the management GUI to
become unresponsive. After the management services have failed over to
the other file module, a refresh of the management GUI in the browser
reestablishes the connection.
2. To shut down and reboot a node by using the command-line interface (CLI)
command, enter:
stopcluster -node mgmt00Xst001 -restart
where X is the logical ID of the node to reboot.
3. The node reboot restarts all services that were previously running g but does
not resume the node on to the cluster.
resumenode mgmt00Xst001
Removing a file module to perform a maintenance action
You can remove an IBM Storwize V7000 Unified file module to perform
maintenance. The procedure that you follow differs slightly, depending on whether
you must unplug the power cables.
Before you begin
If you receive an alert event that requires you to service a file module, use the
following procedure to remove the file module from the system and perform the
required service.
© Copyright IBM Corp. 2011, 2015 91

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals