Run this command twice and compare the values in the Bytes Sent column of
the output. Incremental values indicate that the process is in progress; whereas,
identical values indicate that the restore process has stopped.
Note: The following error message can occur while restoring millions of files:
ANS1030E The operating system refused a TSM request for memory
allocation. 2010-07-09 15:51:54-05:00 dsmc return code: 12
What to do next
If the file system is managed by Tivoli Storage Manager for Space Management,
break down the restore into smaller file patterns or subdirectories that contain
fewer files.
If the file system is not managed by Tivoli Storage Manager for Space
Management, try to force a no-query-restore (NQR) by altering the path that is
specified for the restore. To do this action, include all files by putting a wildcard
("*") after the file system path:
# startrestore "ibm/gpfs0/*"
This example attempts a no query restore, which minimizes memory issues with
the Tivoli Storage Manager client because the Tivoli Storage Manager server does
the optimization of the file list. If you are still unable to restore a larger number of
files at the same time, break down the restore into smaller file patterns or
subdirectories that contain fewer files.
Upgrade recovery
This section covers the recovery procedures that relate to upgrade.
Error codes and recommendations when running the
applysoftware command
If any errors are posted after you issue the applysoftware command, see Table 119
and take the described course of action. Follow these guidelines:
1. Follow the actions in the order presented.
2. After each recommended fix, restart the upgrade by issuing the applysoftware
command again. If the action fails, try the next recommended action.
3. If the recommended actions fail to resolve the issue, call the IBM Support
Center.
Table 119. Upgrade error codes from using the applysoftware command and recommended
actions
Error Code
The applysoftware
command explanation Action
EFSSG1000I The command completed
successfully.
None.
EFSSG4100 The command completed
successfully.
None.
EFSSG4101 The required parameter was
not specified.
Check the command and
verify that the parameters
are entered correctly.
416 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals