Procedure
1. Verify that the node that the multipathd event occurred against is the passive
management node. If the node that experiences the multipathd problems is the
active node, then perform the management node failover procedure. See
“Performing management node role failover on a “good” system” on page 184.
2. Reboot the file module. See “Rebooting a file module” on page 91.
Diagnosing a multipath event
The multipath -ll command verifies that all storage devices are either active or
not active.
The following output shows that all storage devices are active.
[root@yourmachine.mgmt001st001 ~]# multipath -ll
array1_sas_89360007 (360001ff070e9c0000000001989360007) fm-0 IBM,2073-720
[size=3.1T][features=1 queue_if_no_path][hwhandler=0][rw]
\_ round-robin 0 [prio=50][active]
\_ 6:0:0:0 sdb 8:16 [active][ready]
\_ round-robin 0 [prio=10][enabled]
\_ 8:0:0:0 sdg 8:96 [active][ready]
array1_sas_89380009 (360001ff070e9c0000000001b89380009) fm-1 IBM,2073-720
[size=3.1T][features=1 queue_if_no_path][hwhandler=0][rw]
\_ round-robin 0 [prio=50][active]
\_ 6:0:0:2 sdd 8:48 [active][ready]
\_ round-robin 0 [prio=10][enabled]
\_ 8:0:0:2 sdi 8:128 [active][ready]
The following output shows that the storage devices are not active.
[root@kd27lf6.mgmt002st001 ~]# multipath -ll
mpathq (360050768029180b06000000000000007) dm-8 IBM,2145
size=2.5G features=1 queue_if_no_path hwhandler=0 wp=rw
| `- 5:0:0:7 sdr 65:16 failed ready running
`- 6:0:0:7 sdi 8:128 failed ready running
mpathp (360050768029180b06000000000000005) dm-3 IBM,2145
size=2.5G features=1 queue_if_no_path hwhandler=0 wp=rw
| `- 5:0:0:5 sdp 8:240 failed ready running
`- 6:0:0:5 sdg 8:96 failed ready running
The output [active][ready] identifies an active device. The output failed ready
running identifies a device that is not active.
Recovering from an NFSD service error
Use this procedure to recover from an NFSD service error.
About this task
This recovery procedure starts the NFSD when it is down.
Procedure
1. Log in as a CLI user with privileged authority.
2. Issue the sc service nfsd start command.
3. If the problem persists, restart the node.
4. If the restart action does not resolve the issue, contact the next level of support.
Recovering from an SCM error
Use this procedure to recover from a service configuration management (SCM)
error.
Chapter 7. Recovery procedures 407

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals