If all nodes show either node error 550 or node error 578, you might need to
perform a system recovery. See ā€œRecover system procedureā€ on page 380 for more
details.
For more information about determining and solving block storage problems that
relate to the control enclosure, see ā€œResolving a problemā€ on page 236.
Check the intrasystem connectivity by using the management GUI. Navigate to
Monitoring > System. Use the interactive graphic to determine the connection
state by hovering over each connection in the graphic.
If either of the Fibre Channel links from the file modules shows an error or
degraded state, see ā€œFibre Channel connectivity between file modules and control
enclosureā€ on page 72.
If mgmt0, the direct Ethernet link between the file modules, shows an error or
degraded state, see ā€œEthernet connectivity between file modulesā€ on page 65.
If one or both of the Fibre Channel links from the file module to the control
enclosure show an error or a degraded state, see ā€œEthernet connectivity from file
modules to the control enclosureā€ on page 68.
Check the core component health. Navigate to Monitoring > System Details >
Interface Nodes > nodename > NAS Services. In the Status panel, check the CTDB
state and the GPFS state.
If the GPFS state is Active, but the CTDB state is not Active, see ā€œChecking CTDB
healthā€ on page 187; otherwise, see ā€œChecking the GPFS file system mount on each
file moduleā€ on page 189.
If you have lost access to the files, but there is no sign that anything is wrong with
the Storwize V7000 Unified system, see ā€œHost to file modules connectivityā€ on
page 63.
Installation troubleshooting
This topic provides information for troubleshooting problems encountered during
the installation.
Software issues are often reported through CLI commands at system configuration
and through error codes. Power problems can often be solved through identifying
visual symptoms.
Problems with initial setup
This topic helps you to solve initial setup problems.
About this task
If USB flash drive is missing or faulty:
v Contact the IBM Support Center.
v Install the latest InitTool.exe (or reinstall if tool is not launching). Go to
http://www-933.ibm.com/support/fixcentral/options and select the following
options to locate the tool. The options are listed under the Select product tab, at
the bottom of the page:
– Product Group: Storage Systems
48 Storwize V7000 Unified: Problem Determination Guide 2073-720