EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
Table 72. Storwize V7000 Unified Gen1 model numbers (continued)
Machine
type/model Description
2076-212 Storwize V7000 Unified expansion enclosure for 3.5-inch drives
2076-224 Storwize V7000 Unified expansion enclosure for 2.5-inch drives
Storwize V7000 Unified Gen2 refers to the newer generation of enclosures in the
following table:
Table 73. Storwize V7000 Unified Gen2 model numbers
Machine
type/model Description
2076-524 Storwize V7000 Unified control enclosure, with up to 24 2.5-inch (6.35
cm) drives
2076-12F Storwize V7000 Unified expansion enclosure for up to 12 3.5-inch (8.89
cm) drives
2076-24F Storwize V7000 Unified expansion enclosure for 2.5-inch drives
Problem: Cannot initialize or create a Storwize V7000 Gen2
clustered system
Use this information if your attempt to create a Storwize V7000 Gen2 clustered
system failed.
The failure is reported regardless of the method that you used to create a system:
v System initialization wizard (using the technician port of a node canister)
v USB flash drive
v Management console
v Service assistant
v Service command line
To prevent accidental loss of volumes, a system cannot be initialized on an
enclosure that is already configured in an existing system. Check the following
details using the service assistant to confirm that the enclosure is not already
configured in a system:
v The node canister that you are attempting to create a clustered system on must
be in candidate state.
v The partner node canister in the control enclosure must not be in active state.
v The latest system ID of the control enclosure must be 0. If the partner node is in
active state, see Start here: Use the management GUI recommended actions. If
the partner code is not in the active state and the node canister on which you
are attempting to create the system is not in service state, see “Procedure: Fixing
node errors” on page 271.
Problem: Cannot initialize or create a Storwize V7000 Gen1
clustered system
If your attempt to create a system has failed, there are several possible solutions
depending on the current state of the storage system.
Note: This clustered storage system is different from the file system cluster on the
file modules.
Chapter 5. Control enclosure 241

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI