EasyManua.ls Logo

IBM Storwize V7000 Unified - Example that Shows that Mirroring Is Re-Synchronizing

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If a drive were not synchronized, the status might appear like the status shown
in Figure 47 on page 103:
Mirror Information: <---
Volume ID : 3
Status of volume : Resyncing (RSY) <---
RAID level : 1
Size (in MB) : 285148
Physical hard disks (Target ID) : 6 5 <---
Current operation : Synchronize <---
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 583983104
Number of remaining sectors : 553462899
Percentage complete : 5.23% <---
Drive Information:
Total number of drives found: 2
Target on ID #5
Device is a Hard disk
Enclosure # : 1
Slot # : 1
Connector ID : 1
Target ID : 5
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Target on ID #6 <---
Device is a Hard disk
Enclosure # : 1
Slot # : 0
Connector ID : 0
Target ID : 6
State : Online (ONL)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Figure 46. Example that shows that mirroring is re-synchronizing
102 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Related product manuals