8. See Figure 49 on page 105 for an example of a Self-Monitoring, Analysis and
Reporting Technology (SMART) error found for a hard drive. SMART adds
monitoring and troubleshooting functionality by automatically checking a disk
drive's health and reporting potential problems. If any SMART errors are
detected for a hard drive, you can see the status in the section for Error
Information as shown in Figure 49 on page 105.
Note: In Figure 49 on page 105 the hard disk drive with Target ID #6 has a
ASC/ ASCQ error of 05/00.
For isolation and the repair of hard disk problems, refer to “Troubleshooting
the System x3650” in the IBM Storwize V7000 Unified Information Center.
For a list of SMART (ASC/ASCQ) error codes and their descriptions, go to
“SMART ASC/ASCQ error codes and messages” on page 105.
Mirror Information:
NOTICE: The mirror is not created/configured. <---
Drive Information:
Total number of drives found: 2
Target on ID #4
Device is a Hard disk
Enclosure # : 1
Slot # : 1
Connector ID : 1
Target ID : 4
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Target on ID #6
Device is a Hard disk
Enclosure # : 1
Slot # : 0
Connector ID : 0
Target ID : 6
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Figure 48. Example that shows that the mirror is not created
104 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals