Table 50. Originating file module specific software code Code 1, 3, 5.
Listing devices for variable C in the specific software code sequence of ABBCDDDD.
C = Originating specific software code in sequence ABBCDDDD
Code Device
0 Red Hat Linux
1 GPFS
2 CIFS server
3 CTDB
4 SoFS
5 winbind
6 multipathd
7 nscd
8 sshd
9 httpd
A vsftpd
B nmbd
C nfsd
D cpu
E multipath/disk
Table 51. Storage enclosure hardware code Code 6.
Listing devices for variable C in the specific hardware code sequence of ABBCDDDD.
C = Originating specific software code in sequence ABBCDDDD
Code Device
0 Generic value for storage enclosure hardware
1 Disk drive in controller drawer
2 RAID controller card 0
3 RAID controller card 1
4 Power supply in controller drawer
5 RAID array/LUN issue in controller drawer
6 Disk drive in expansion drawer
7 Expansion fibre channel card 0
8 Expansion fibre channel card 1
9 Power supply in expansion drawer
A RAID array/LUN issue in expansion drawer
Severity of the error
The element x indicates the severity of the error. The value x can be:
v A for Action: GUI error messages. The user must perform a specific action.
v C for Critical: A critical error occurred which must be corrected by the user or
system administrator.
Chapter 4. File module 119

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals