Table 46. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
5D 60 FIRMWARE IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 61 FIRMWARE IMPENDING FAILURE DRIVE ERROR RATE TOO HIGH
5D 62 FIRMWARE IMPENDING FAILURE DATA ERROR RATE TOO HIGH
5D 63 FIRMWARE IMPENDING FAILURE SEEK ERROR RATE TOO HIGH
5D 64 FIRMWARE IMPENDING FAILURE TOO MANY BLOCK REASSIGNS
5D 65 FIRMWARE IMPENDING FAILURE ACCESS TIMES TOO HIGH
5D 66 FIRMWARE IMPENDING FAILURE START UNIT TIMES TOO HIGH
5D 67 FIRMWARE IMPENDING FAILURE CHANNEL PARAMETRICS
5D 68 FIRMWARE IMPENDING FAILURE CONTROLLER DETECTED
5D 69 FIRMWARE IMPENDING FAILURE THROUGHPUT PERFORMANCE
5D 6A FIRMWARE IMPENDING FAILURE SEEK TIME PERFORMANCE
5D 6B FIRMWARE IMPENDING FAILURE SPIN-UP RETRY COUNT
5D 6C FIRMWARE IMPENDING FAILURE DRIVE CALIBRATION RETRY
COUNT
5D FF FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
5E 00 LOW POWER CONDITION ON
5E 01 IDLE CONDITION ACTIVATED BY TIMER
5E 02 STANDBY CONDITION ACTIVATED BY TIMER
5E 03 IDLE CONDITION ACTIVATED BY COMMAND
5E 04 STANDBY CONDITION ACTIVATED BY COMMAND
5E 05 IDLE_B CONDITION ACTIVATED BY TIMER
5E 06 IDLE_B CONDITION ACTIVATED BY COMMAND
5E 07 IDLE_C CONDITION ACTIVATED BY TIMER
5E 08 IDLE_C CONDITION ACTIVATED BY COMMAND
5E 09 STANDBY_Y CONDITION ACTIVATED BY TIMER
5E 0A STANDBY_Y CONDITION ACTIVATED BY COMMAND
65 00 VOLTAGE FAULT
67 0A SET TARGET PORT GROUPS COMMAND FAILED
67 0B ATA DEVICE FEATURE NOT ENABLED
74 08 DIGITAL SIGNATURE VALIDATION FAILURE
74 0C UNABLE TO DECRYPT PARAMETER LIST
74 10 SA CREATION PARAMETER VALUE INVALID
74 11 SA CREATION PARAMETER VALUE REJECTED
74 12 INVALID SA USAGE
74 30 SA CREATION PARAMETER NOT SUPPORTED
74 40 AUTHENTICATION FAILED
74 71 LOGICAL UNIT ACCESS NOT AUTHORIZED
74 79 SECURITY CONFLICT IN TRANSLATED DEVICE
116 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI