About this task
The file module comes with one riser-card assembly that contains two to three PCI
slots. See http://www.ibm.com/servers/eserver/serverproven/compat/us/ for a
list of riser-card assemblies that you can use with the file module.
To remove a riser-card assembly, complete the following steps.
Procedure
1. Read the safety information that begins on page Safety and “Installation
guidelines” on page 94.
2. Follow the procedure in “Removing a file module and disconnecting power” on
page 92 to suspend the file module from the cluster and shut it down and
disconnect all power cords and external cables.
3. Slide the file module out of the rack.
4. Remove the file module cover. For more information, see Removing the cover.
5. Grasp the riser-card assembly at the front tab and rear edge and lift it to
remove it from the file module. Place the riser-card assembly on a flat,
static-protective surface.
Installing a PCI riser-card assembly
IBM authorized service providers can install a PCI riser-card assembly in the file
module. The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
The file module provides two PCI riser-card slots on the system board. The
following information indicates the riser-card slots:
v The file module come with one PCI Express
®
riser-card assembly installed.
v A PCI Express riser-card assembly has a black connector and supports PCI
Express adapters.
v PCI riser slot 1 (the farthest slot from the power supplies). You must install a
PCI riser-card assembly in slot 1.
v PCI riser slot 2 (the closest slot to the power supplies). You must not install a
PCI riser-card assembly in slot 2.
To install a riser-card assembly, complete the following steps.
142 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals