EasyManuals Logo

IBM Storwize V7000 Unified Problem Determination Guide

IBM Storwize V7000 Unified
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #250 background imageLoading...
Page #250 background image
Table 62. Cache statistics collection for volumes and volume copies (continued)
Statistic Acronym
Statistics for
volume
cache
Statistics for
volume
copy cache
Statistics for
volume
cache
partition
Statistics for
volume
copy cache
partition
Statistics for
the Node
Overall
Cache
Cache
statistics for
mdisks
Units and
state
Write Cache
Fullness
Average
wfav Yes %,
non-
cumulative
Write Cache
Fullness Max
wfmx Yes %,
non-
cumulative
Write Cache
Fullness Min
wfmn Yes %,
non-
cumulative
Read Cache
Fullness
Average
rfav Yes %,
non-
cumulative
Read Cache
Fullness Max
rfmx Yes %,
non-
cumulative
Read Cache
Fullness Min
rfmn Yes %,
non-
cumulative
Pinned
Percent
pp Yes Yes Yes Yes Yes % of total
cache
snapshot,
non-
cumulative
data transfer
latency
average
tav Yes Yes µs capped
9999999,
non-
cumulative
Track Lock
Latency
(Exclusive)
Average
teav Yes Yes µs capped
9999999,
non-
cumulative
Track Lock
Latency
(Shared)
Average
tsav Yes Yes µs capped
9999999,
non-
cumulative
Cache I/O
Control Block
Queue Time
hpt Yes Average µs,
non-
cumulative
Cache Track
Control Block
Queue Time
ppt Yes Average µs,
non-
cumulative
Owner Remote
Credit Queue
Time
opt Yes Average µs,
non-
cumulative
Non-Owner
Remote Credit
Queue Time
npt Yes Average µs,
non-
cumulative
Admin Remote
Credit Queue
Time
apt Yes Average µs,
non-
cumulative
Cdcb Queue
Time
cpt Yes Average µs,
non-
cumulative
222 Storwize V7000 Unified: Problem Determination Guide 2073-720

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals