Attention: A powered-on enclosure must not have a power supply removed for
more than five minutes because the cooling does not function correctly with an
empty slot. Ensure that you have read and understood all these instructions and
have the replacement available, and unpacked, before you remove the existing
power supply.
Even though many of these components are hot-swappable, they are intended to
be used only when your system is not active (no I/O operations). If your system is
powered on and processing I/O operations, go to the management GUI and follow
the fix procedures. Initiating the replacement actions without the assistance of the
fix procedures can result in loss of data or loss of access to data.
Be careful when you are replacing the hardware components that are located in the
back of the system that you do not inadvertently disturb or remove any cables that
you are not instructed to remove.
Ensure that you are aware of the procedures for handling static-sensitive devices
before you replace the power supply.
About this task
To replace the power supply unit in an expansion enclosure, perform the following
steps:
Procedure
1. Read the safety information to which “Preparing to remove and replace parts”
on page 295 refers.
2. Examine the Identify LED that is lit on the front of the enclosure to identify
the correct enclosure.
3. Turn off the power to the power supply unit using the switch at the back of
the unit.
4. Disconnect the cable retention bracket and the power cord from the power
supply that you are replacing.
5. Remove the power supply unit. Record the orientation of the power supply
unit. Power supply unit 1 is top side up, and power supply unit 2 is inverted.
a. Depress the black locking catch from the side with the colored sticker as
shown in Figure 90 on page 314.
Chapter 5. Control enclosure 313

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI