Before you begin this procedure, read the recover system procedure introductory
information; see “Recover system procedure” on page 380.
About this task
Attention: This service action has serious implications if not completed properly.
If at any time an error is encountered not covered by this procedure, stop and call
the support center.
Run the recovery from any node canisters in the system; the node canisters must
not have participated in any other system.
Note: Each individual stage of the recovery procedure can take significant time to
complete, depending on the specific configuration.
Procedure
1. Point your browser to the service IP address of one of the node canisters.
If the IP address is unknown or is not configured, assign an IP address using
the initialization tool; see “Procedure: Changing the service IP address of a
node canister” on page 271.
2. Log on to the service assistant.
3. Check that all node canisters that were members of the system are online and
have candidate status.
If any nodes display error code 550 or 578, remove their system data to place
them into candidate status; see “Procedure: Removing system data from a node
canister” on page 270.
4. Select Recover System from the navigation.
5. Follow the online instructions to complete the recovery procedure.
a. Verify the date and time of the last quorum time. The time stamp must be
less than 30 minutes before the failure. The time stamp format is
YYYYMMDD hh:mm, where YYYY is the year, MM is the month, DD is the
day, hh is the hour, and mm is the minute.
Attention: If the time stamp is not less than 30 minutes before the failure,
call the support center.
b. Verify the date and time of the last backup date. The time stamp must be
less than 24 hours before the failure. The time stamp format is YYYYMMDD
hh:mm, where YYYY is the year, MM is the month, DD is the day, hh is the
hour, and mm is the minute.
Attention: If the time stamp is not less than 24 hours before the failure,
call the support center.
Changes that are made after the time of this backup date might not be
restored.
Results
Any one of the following categories of messages might be displayed:
v T3 successful
The volumes are back online. Use the final checks to get your environment
operational again.
v T3 recovery completed with errors
Chapter 5. Control enclosure 385

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals