Table 120. Upgrade error codes and recommended actions (continued)
Error
Code Explanation Action
01E7 Unable to ping node
1. Verify that the node is powered on. If
yes, ping the node.
2. Restart the node and then, ping the
node.
3. Check the network connections and
correct them, if required.
4. Contact IBM Remote Technical
Support.
01E8 Unable to apply firmware to
Emulex adapters.
Contact IBM Remote Technical Support.
01FF NAS upgrade cannot continue
because a system upgrade is in
progress.
Enter svcinfo lsupdate to check the state
of the system upgrade.
v If the status is system_updating or
system_completing, allow the upgrade
to complete. Then restart the NAS
upgrade from the file modules.
v If the status is system_prepared, stop
the current upgrade by entering
svctask applysoftware -abort. Then
restart the NAS upgrade from the file
modules.
If lsupdate is not available enter svcinfo
lsupdate to check the state of the system
upgrade.
v If the status is upgrading, allow the
upgrade to complete. Then restart the
NAS upgrade from the file modules.
v If the status is prepared, stop the
current upgrade by entering svctask
applysoftware -abort. Then restart the
NAS upgrade from the file modules.
0200 A failure has occurred while
reading the registry.
1. Use lsnode to check the status of
CTDB and GPFS for the nodes.
Reboot the unhealthy node and wait
for the node to be up again. Then,
again check the health of the node
with lsnode.
2. Contact IBM Remote Technical
Support.
0201 Unable to open CIM configuration
file.
Contact IBM Remote Technical Support.
0202 Unable to update CIM
configuration.
Contact IBM Remote Technical Support.
0511 Unable to disable CNSCM
monitoring.
Contact IBM Remote Technical Support.
0513 Management service could not be
stopped
Contact IBM Remote Technical Support.
0514 Database backup failed Contact IBM Remote Technical Support.
0515 Database backup failed Contact IBM Remote Technical Support.
Chapter 7. Recovery procedures 425

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI