To find the file module's current record of the control enclosure system IP address,
use the Storwize V7000 Unified management CLI to issue the lsstoragesystem
command. Here is an example:
>ssh admin@<management_IP>
[kd01ghf.ibm]$ lsstoragesystem
name primaryIP secondaryIP id
StorwizeV7000 9.11.137.130 9.11.137.130 00000200A2601508
EFSSG1000I The command completed successfully.
If the primary and secondary IP address shown by the lsstoragesystem CLI do
not match the system IP addresses shown in the output of the lssystemip CLI
command, then it is necessary to update the record. The chstoragesystem
command changes the file module record of the control enclosure system IP. Here
is an example:
>[kd01ghf.ibm]$ chstoragesystem --ip1 9.71.18.136 --ip2 9.71.18.136
EFSSG1000I The command completed successfully.
Verify that communication from the file module to the control enclosure is now
possible by running the lssystemip command on the Storwize V7000 Unified
management CLI:
>ssh admin@<managment IP address>
[kd01ghf.ibm]$ lssystemip
Changing the cluster IP of the file modules:
If the cluster IP address of the file modules is not known, or has been incorrectly
set, the value can be changed by logging into the system using a console.
Connect a keyboard and monitor directly into the front of the file module which is
the active management node. Login as a user with administrative access rights:
v Login: admin
v Password: <default is admin>
View the current cluster IP setting using the lsnwmgt command:
>$ lsnwmgt
[kd27lf5.ibm]$ lsnwmgt
Interface Service IP Node1 Service IP Node2 Management IP Network Gateway VLAN ID
ethX0 9.115.160.221 9.115.160.222 9.115.160.220 255.255.248.0 9.115.167.254
EFSSG1000I The command completed successfully
You may receive the following error:
$ lsnwmgt
EFSSG0026I Cannot execute commands because Management Service is stopped.
Use startmgtsrv to restart the service.
This is an indication that the node you are currently connected to is not the active
management node. Plug the keyboard and monitor into the other node, login again
and retry the lsnwmgt command.
To change the file module cluster IP to its new value, use the chnwmgt command:
Here is an example:
>$ chnwmgt mgtip 9.115.160.210 -- netmask 255.255.255.0 gateway 9.115.160.254
Checking the physical status of the Ethernet ports:
Chapter 3. Getting started troubleshooting 71

Table of Contents

Other manuals for IBM Storwize V7000 Unified

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified and is the answer not in the manual?

IBM Storwize V7000 Unified Specifications

General IconGeneral
ModelIBM Storwize V7000 Unified
Storage TypeUnified Storage
RAID LevelsRAID 0, 1, 5, 6, 10
Form Factor2U
Drive Types SupportedSAS, SSD
Maximum Drives504
Network ProtocolsiSCSI, FC, FCoE
Drive Bays24 per enclosure
Host Interface8 Gb FC, 1 Gb/10 Gb iSCSI
File ProtocolsNFS, CIFS
Block ProtocolsiSCSI, Fibre Channel
TypeUnified Storage
Maximum Host Ports16
Operating System SupportVMware, Microsoft Windows, Linux, AIX
Data ServicesThin provisioning, replication
Power SupplyRedundant power supplies
Host Interfaces8 Gbps Fibre Channel, 10 Gbps iSCSI, 1 Gbps iSCSI

Related product manuals