Test cycles
(TEST CYCLES item on the SERVICE menu)
Through this option it is possible to set different test procedures according the technician needs. The following display is shown:
TEST CYCLE OFF +
SPECIAL CYCLE
CONTINUOUS CYCLE
NO VACUUM CYCLE -
Use key
+ / - to select the test mode, push the key to confirm.
TEST CYCLE OFF mode allows to disable the test mode previously set.
SPECIAL CYCLE mode enable a full test of the sterilizer. As confirmed the choice, exit from the Setup menu, select a cycle and enter the
START command. The sterilizer will start an automatic sequence of any available cycle.
At the end of each cycle the report will be printed.
CONTINUOUS CYCLE mode enable a test based on the continuous repetition of the cycle that will be selected after the exit from the Setup
menu.
NO VACUUM CYCLE mode enable a test based on the cycle that will be selected after the exit from the Setup menu, and characterized only with
pressure pulses and without pre-vacuum and vacuum drying phases.
e See Attachment O for the notes about the use of these test cycles.