SP1-XXX (Feed) 
 
D0CA/D0C9/D0C8/D0CB  3-18  SM Appendices 
SP No.  Large Category  Small Category  ENG 
or CTL 
[Min to 
Max/Init./Step] 
1: ON 
1-120-001  Fuser Logs 
acquisition 
Mode Switch  ENG*  [0 to 1 / 0 / 1/step] 
1-120-002  Fuser Logs 
acquisition 
Period Switch  ENG*  [0 to 4 / 0 / 1/step] 
1-131-001  Continuous Print 
Mode Switch 
Feed Permit Condition Setting  ENG*  [0 to 2 / 1 / 1/step] 
0: Productivity Mode 
1: Fusing Quality 
Mode 1 
2: Fusing Quality 
Mode 2 
1-132-012  Voltage Detection  Voltage Detection  ENG*  NA: [0.0 to 650.0 / 
117.0 / 0.1V/step] 
TWN: [0.0 to 650.0 / 
107.0 / 0.1V/step] 
KOR: [0.0 to 650.0 / 
227.0 / 0.1V/step] 
EU: [0.0 to 650.0 / 
227.0 / 0.1V/step] 
CHN: [0.0 to 650.0 / 
227.0 / 0.1V/step] 
AS: [0.0 to 650.0 / 
227.0 / 0.1V/step] 
1-132-014  Voltage Detection  Max  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-132-015  Voltage Detection  Min  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-132-016  Voltage Detection  Latest  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-132-017  Voltage Detection  SC Detection  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-132-018  Voltage Detection  Max(standby)  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-132-019  Voltage Detection  Min(standby)  ENG*  [0.0 to 350.0 / 0.0 / 
0.1V/step] 
1-135-001  Inrush Control  Inrush Control  ENG*  [0 to 1 / 0 / 1/step] 
1-136-001  Engy Svg Paper  Control ON/OFF  ENG*  [0 to 1 / 1 / 1/step]