SP1-XXX (Feed)
SM Appendices
3-19 D0CA/D0C9/D0C8/D0CB
Appendices
SP Mode Tables
SP No. Large Category Small Category ENG
or CTL
[Min to
Max/Init./Step]
Feed Judg. 0: OFF
1: ON
1-141-001 Fusing SC Issue
Time Info
SC Number ENG* [0 to 99999 / 0 /
1/step]
1-141-101 Fusing SC Issue
Time Info
Heating Roller Temperature
1:Center
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-104 Fusing SC Issue
Time Info
Heating Roller Temperature
1:End
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-107 Fusing SC Issue
Time Info
Press Roller Temperature 1 ENG* [-100 to 260 / 0 /
1deg/step]
1-141-108 Fusing SC Issue
Time Info
Press Roller: End R
Temperature 1
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-109 Fusing SC Issue
Time Info
Press Roller: End F
Temperature 1
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-110 Fusing SC Error
Time Info
NC Sensor: Center
Atmosphere Temp 1
ENG* [-100 to 300 / 0 /
1deg/step]
1-141-111 Fusing SC Error
Time Info
Fuser State Det 1 ENG* [0 to 100 / 0 / 1/step]
1-141-112 Fusing SC Error
Time Info
Heater1 Duty Det 1 ENG* [0 to 100 / 0 /
1%/step]
1-141-113 Fusing SC Error
Time Info
NC Sensor: Center Det Temp
AD 1
ENG* [0 to 2000 / 0 /
1/step]
1-141-114 Fusing SC Error
Time Info
NC Sensor: Center
Atmosphere Temp AD 1
ENG* [0 to 2000 / 0 /
1/step]
1-141-151 Fusing SC Issue
Time Info
Heating Roller Temperature
2:Center
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-154 Fusing SC Issue
Time Info
Heating Roller Temperature
2:End
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-157 Fusing SC Issue
Time Info
Press Roller Temperature 2 ENG* [-100 to 260 / 0 /
1deg/step]
1-141-158 Fusing SC Issue
Time Info
Press Roller.End R
Temperature 2
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-159 Fusing SC Issue
Time Info
Press Roller.End F
Temperature 2
ENG* [-100 to 260 / 0 /
1deg/step]
1-141-160 Fusing SC Error
Time Info
NC Sensor: Center
Atmosphere Temp 2
ENG* [-100 to 300 / 0 /
1deg/step]
1-141-161 Fusing SC Error Fuser State Det 2 ENG* [0 to 100 / 0 / 1/step]