EasyManuals Logo

SKF Microlog GX Series User Manual

SKF Microlog GX Series
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #184 background imageLoading...
Page #184 background image
Data Recorder Module
How to Perform a Data Recorder Measurement
Rec. Time (s)Specify the number of seconds to record the vibration signal.
Rec. Mode – (Manual, CH1 Level, or Tacho) Works with the Input field. Specify
whether to initiate data recording manually, or to use a CH1 trigger level to initiate
recording, or to use a tachometer for triggering data recording (if Input is set to CH1 &
Tacho). (in this case, as soon as the Microlog receives a tachometer signal, data
recording initiates).
Save If desired, from the measurement setup screen, you may press the Save
function button to save the measurement setup for easy reuse in the future. Reference
Chapter 4, The Analyzer Module section on Saving Analyzer Measurement Results
for details on how to save your measurement setup.
After you are finished with your measurement setup changes, press the Start
function button to begin the measurement using the new settings. The
measurement is performed and the initial measurement results display.
Function button options for completing, viewing and saving the measurement’s results
operate as previously described in this chapter’s Collecting Recorder Measurements
Using the Default Measurement Setup section. Reference this previous section for
details.
6 - 8 SKF Microlog - GX Series
User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF Microlog GX Series and is the answer not in the manual?

SKF Microlog GX Series Specifications

General IconGeneral
BrandSKF
ModelMicrolog GX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals