Conformance Check Module
How to Set Up or Customize Conformance Test Templates
Triax Sensor – Check this box if a triaxial sensor is to be used. Note that checking this
box enables further parameters to be entered:
• The direction to be associated with each channel. For the SKF 3073 M6 triaxial
accelerometer, channels X, Y and Z corresponds to direction ‘1’, ‘2’ and ‘3’
respectively.
• Two additional Sensitivity entry boxes appear, totaling 3, one for each input
channel.
Also note that checking the Triax Sensor box, disables custom directions under the
“Location” sub-tab.
“Measurement - Locations” Sub-tab
Figure 9 - 7.
Measurement – Transducer Configuration Tab.
No. Locations – Specifies the number of measurement locations on the tested
machine. Typically, each bearing is a test location.
Directions – Default options are Horizontal, Vertical, and Axial. This specifies at which
sensor orientation(s) to collect data for each measurement location. Create up to 32
custom directions by simply entering text in the Labels column. Use the drop-down by
clicking on an entry in the Enabled column to Enable, Disable or delete a direction.
If Triax Sensor (on the “Measurement - Transducer” tab) has
been enabled, then directions cannot be named. Instead,
Horizontal, Vertical and Axial readings will be taken for each
location.
SKF Microlog - GX Series 9 - 7
User Manual