Non ROUTE
How to Collect Pre-set Non ROUTE Measurements
For Accel, Accel Time, Velocity, and gE pre-set measurement types, the following
standard settings are taken from the current selected ROUTE measurement:
Sensitivity
Coupling
Detection
Window
Accel – Performs a “standard” type vibration Acceleration measurement.
Measurement parameters are set to:
Units - Accel (Gs)
Display Format – Spectrum
High-pass frequency - 1.1 Hz
Fmax - 10 kHz
Lines/Samples - 800 Lines
Averages – 4
Input Channel – CH1
Overlap – 50%
Ext. Trigger Slope – Positive
Trigger Level – 2 V
Bin Zeroing – On
Type - Spectral
Accel Time – Performs the same “standard” type vibration Acceleration measurement,
but collects time waveform data. Measurement parameters are set to:
Units - Accel (Gs)
Display Format – Time
High-pass frequency - 1.1 Hz
Fmax - 8 kHz
Lines/Samples – 6400 Lines / 16384 Samples
Averages – 4 (time sync.) If a trigger is defined for the active ROUTE point, if
no trigger is detected only 1 average is taken.
Input Channel – CH1
Overlap – 50%
Ext. Trigger Slope – Positive
Trigger Level – 2 V
Bin Zeroing – On
Type – Time
Velocity – Performs a “standard” type acceleration to velocity vibration measurement.
Measurement parameters are set to:
Units – A -> V
Display Format – Spectrum
High-pass frequency - 1.1 Hz
Fmax - 1 kHz
Lines/Samples - 400 Lines
Averages – 4
Input Channel – CH1
Overlap – 50%
A - 4 SKF Microlog - GX Series
User Manual