ID 442426.04 152WE KEEP THINGS MOVING
Basic properties
8
Manual SD6
Parameters – quick access
Quick access gives you direct access to the status of the most important
(diagnostic) parameters. This level consists of a start display and four
overviews of specific content:
Status display 1
provides information about the causes of a possible switch on
disable; status display 2
provides information about the analog and binary
inputs and outputs; status display 3
for general drive controller data including
type, firmware, integrated option modules, etc. You can navigate within this
level with the right and left arrow keys.
Press "ESC" to reach the parameters associated with the values that appear in
the start display. These parameters are individually configurable.
Parameter groups
Parameters are combined together in groups based on their functional
properties, for example "Drive controller," "Motor," "Machine," "Terminals",
etc.You can navigate within this level with the right and left arrow keys; Select
one of the possible groups with "OK.
Parameters
You can navigate in a parameter group with the upper and lower arrow keys.
Select one of the possible parameters with "OK." To change a parameter value,
choose the corresponding character position with the right and left arrow keys,
then select the new value with the upper and lower arrow keys. Accept
changes with "OK" or reject them with "Esc.
8.2.1.3 Status display
Note that the default setting of the status display depends on the application.
The following parameters are displayed in the default setting:
• I80 current position
• E08 n-motor filtered
• E00 I-Motor
• E80 operating condition
To find out which the corresponding parameter addresses for the values in the
status display, press and hold the ESC key in the basic view.
There are two ways to change the status display:
• You can display other parameters: to do this enter the addresses of the
parameters you want to display in parameter A144.x status display
parameter , for example A10[1] or 1.I400.
• You can use the drive controller display as the output medium of a higher-
level controller: to do this set A142 = 1:Terminal. Then the controller must
describe parameter array A141.x (one parameter element for each display
line). If the controller does not transfer any values, the display remains
empty.
In parameter array A140.x read display lines you can read via the controller
which content is currently being displayed in which line of the display. The
content of a line is represented in a parameter element. Depending on how the
display is configured, not all lines and therefore not all parameter elements will
be filled.
8.2.1.4 Languages
You can select the language for the display in parameter A12. German, English
and French are currently available for selection.
Information
Note that a modified parameter value can only be saved so it will be
retained through a power failure with the save key on the control
unit.