ID 442426.04 199WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
9.8.3.2 AE2
Tau for reference value smoothing for analog input 2.
Values of the analog input.
Element 0: Terminal value of the analog input before filtering.
Element 1: Filtered value of the analog input before calibration.
Element 2: Calibrated value of the analog input.
Zero value of the analog input.
Maximum positive value of the filtered analog input.
Maximum negative value of the filtered analog input.
Deadband value of the analog input.
Minimum percentage value of the calibrated analog input.
Maximum percentage value of the calibrated analog input.
F23 AE2 ref low pass filter version 0
E111 AE2 version 0
F120 Analog input 2 zero value version 0
F121 Analog input 2 maximum positive value version 0
F122 Analog input 2 maximum negative value version 0
F123 Analog input 2 deadband value version 0
F124 Analog input 2 minimum % value version 0
F125 Analog input 2 maximum % value version 0