Diagnosis
16
Manual SD6
16.59 *ConfigStartERROR unknown limit
16.60 *ConfigStartERROR unknown post-wr
Triggering Level Response
The versions of configuration and firmware do not
match.
The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close. The brake chopper is
turned off.
Possible cause Test Measure Confirmable
The configuration saved in the
Paramodule originates from a newer
firmware that recognizes more limit
value functions.
Apply a suitable configuration or firmware
via DriveControlSuite.
No
Triggering Level Response
The versions of configuration and firmware do not
match.
The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close. The brake chopper is
turned off.
Possible cause Test Measure Confirmable
The configuration saved in the
Paramodule originates from a newer
firmware that recognises more
PostWrite functions.
Apply a suitable configuration or firmware
via DriveControlSuite.
No