ID 442426.04 34WE KEEP THINGS MOVING
Technical data
4
Manual SD6
4.4 Transportation, storage and operating
environment
NOTICE
Material damage!
The DC link capacitors in devices of sizes 0, 1 and 2 can lose their electrical
strength through long storage times. Considerable material damage can arise
from a reduced electrical strength of the DC link capacitors when switching on.
Use devices in storage annually or before startup.
Surrounding operating
temperature
0 °C to 45 °C for nominal data
Storage/
transport temperature
-20 °C to +70 °C
Maximum change: 20 K/h
Relative humidity Maximum relative humidity 85 %, non-
condensing
Installation altitude Up to 1000 m above sea level without restrictions
Pollution degree Pollution degree level 2 as per EN 50178
Ventilated Installed fan
Vibration (operation) 5 Hz f 9 Hz: 0.35 mm
9 Hz f 200 Hz: 1 m/s
2
Vibration (transport) 5 Hz f 9 Hz: 3.5 mm
9 Hz f 200 Hz: 10 m/s
2
200 Hz f 500 Hz: 15 m/s
2

Table of Contents