ID 442426.04 428WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
16.49 #<Placeholder>
16.50 *ParaModul ERROR:update firmware!
Resolution Level Response
A program run error was found in the
microprocessor.
Fault The power stage is switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close. The brake chopper is
turned off.
The microprocessor is stopped and all device functions are inoperable.
Possible cause Test Measure Confirmable
Error in code memory (bit dumped,
permanent).
Reestablish the operating conditions at the
time of the error and check whether the error
occurs again.
Reload the application in the drive
controller and save it.
Perform a firmware upgrade.
No
EMC error Check the wiring for EMC-compliant design. Wire according to EMC regulations.
Triggering Level Response
The versions of configuration and firmware do not
match.
The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close. The brake chopper is
turned off.
Possible cause Test Measure Confirmable
Old firmware version Apply a suitable configuration or firmware. No

Table of Contents