Diagnosis
16
Manual SD6
16.36 73:Ax2braketest
Triggering Level Response Counter
The time set in B311 timeout for brake test B300
has elapsed while brake management is active
without the B300 brake test action having been
performed. If B310 = 2: axis-specific is set, the
event only applies to axis 2.
Causes 1 and 2:
Fault
Cause 3:
Message
The power board remains switched off and the drive is
torque-free/force-free. If the air override is inactive, a
possibly existing brake will be controlled to close.
Z73
Cause Description Measure Confirmable
1:B311Timeout The time entered in B311 Timeout for brake
test B300 has elapsed twice without the
B300 Brake test action having been
performed.
Perform the B300 brake test action. Yes
For a duration
of 5 minutes,
to be able to
perform action
B300 brake
test.
2:brakeDefective When performing the brake test action, the
holding torque entered in B304 or B305
could not be applied or the encoder test run
included in the brake test was completed
with errors.
Perform the brake grinding function and
then the brake test.
The motor must be sent in for repair.
Please contact our Service department.
3:Brake test required The time entered in B311 Timeout for brake
test B300 has elapsed once without the
B300 brake test action having been
performed.
Perform the B300 brake test action.