ID 442426.04 76WE KEEP THINGS MOVING
Installation
6
Manual SD6
The clearance dimensions noted here apply only to installation without a DL6
Quick DC-Link module. If you would like to operate drive controllers as part of
Quick DC-Link, see the applicable dimensions 6.5 Quick DC-Link.
Requirements:
• Prevent condensation, for example with anti-condensation heating
elements.
• Note that drive controllers in storage must be used annually or no later than
before commissioning.
• For reasons related to EMC, use mounting plates with a conductive surface
(unpainted, etc.).
• Fasten the devices onto the mounting plate with M5 screws.
• Attach the devices vertically.
• Avoid installation above or in the immediate vicinity of heat-generating
devices
such as output deraters or braking resistors.
• To ensure there is sufficient air circulation in the control cabinet, observe
the minimum clearances.
• A contact plan of the system in which the connection of the drive controller
is described must be present.
You need:
• a tool to drill the tapped holes in the mounting plate.
• a tool to tighten the fastening screws.
Drive controller installation
1. If present, install both a terminal module and a communication module
(see section 6.3 Terminal modules).
2. Prepare the mounting plate according to the separately enclosed drilling
diagram.
3. Install the drive controller on the mounting plate. Make certain chips and
oil are cleaned from the mounting plate.
4. Connect the housing ground (see section 4.6.3 Housing ground).
5. Connect the drive controller, terminal module and communication module
according to the contact plan.