EasyManua.ls Logo

Stober SD6 - Page 187

Stober SD6
439 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID 442426.04 187WE KEEP THINGS MOVING
Drive controller
9
Manual SD6
Resistance value of the braking resistor that is used.
Output of the braking resistor that is used.
Thermal time constant of the braking resistor.
The energy dissipated through the braking resistor (in watt-hours) is saved
here in non-volatile memory. This value can be reset with A37.
The maximum value of the thermal utilization of the braking resistor is saved in
non-volatile memory here. This value can be reset with A37.
A21 brake resistor R version 0
A22 brake resistor P version 0
Information
If A22 = 0, the brake chopper is deactivated.
A23 brake resistor thermal version 0
E38 braking energy version 0
E41 i2t braking resistor peak value version 0
Information
- This parameter does not specify the maximum value of E24.
- - E24 is initialized with 80 % when the device starts. By contrast
the parameter based on the model is 0 %.
- For a meaningful maximum value measurement, the braking
resistance when the device starts must be approximately at
ambient temperature.

Table of Contents

Other manuals for Stober SD6