The error category stands for a group of errors:
The Error value specifies the error in an error category. The error values are
specified for each error category in the following.
In error category 00
hex
, the error value is always 00
hex
.
The following errors can occur in error category 01
hex
:
The cause of this error may be a faulty TCP/IP connection. Check the
connection and the network settings. A firewall may also be preventing the
TCP/IP connection. Check (with DriveControlSuite, for example) whether the
teleserver can be reached.
The following errors can occur in error category 02
hex
:
14
hex
A timeout occurred while setting up the HTTP connection.
15
hex
The connection to the teleserver was terminated properly by
DriveControlSuite.
16
hex
The connection to the teleserver is being closed.
17
hex
DriveControlSuite has been connected with the teleserver.
18
hex
The HTTP connection has been started.
19
hex
The underlying TCP/IP connection was interrupted. The
connection is being set up again.
Error category Description
00
hex
No remote maintenance is active or no error has occurred.
01
hex
A socket error was detected (problems in applying the
TCP/IP connection).
02
hex
A firmware error was detected (internal firmware error).
03
hex
An HTTP error was detected (problems on the HTTP
communication level).
04
hex
A TCP/IP error was detected (problems on the TCP/IP
communication level).
05
hex
An error was detected in the teleserver client application.
06
hex
A DNS error was detected (problems with the DNS
resolver).
07
hex
A proxy error was detected (problems with the proxy
settings).
Status
value
Description
Error
value
Description
00
hex
Reserved
01
hex
A TCP/IP error occurred while sending or receiving.
02
hex
A TCP/IP error occurred while sending or receiving.
Error
value
Description
00
hex
Reserved
01
hex
Internal error 1
02
hex
Not enough free memory is available.
03
hex
An internal handle is invalid.
04
hex
An error occurred while running the HTTP application.
05
hex
An internal parameter is invalid.
06
hex
An internal parameter is invalid.
07
hex
An internal parameter is invalid.
08
hex
Not enough free memory is available.
09
hex
Not enough free memory is available.
0A
hex
Not enough free memory is available.
0B
hex
Internal access was denied.
0C
hex
Internal access was denied.