ID 442426.04 51WE KEEP THINGS MOVING
Technical data
4
Manual SD6
Connecting Quick DC-Link – drive controller
The DC link capacitors of exactly two drive controllers can be connected via the
SD6 output terminals. To connect the capacitors of multiple drive controllers,
you need a separate module DL6. (see also 6.5 Quick DC-Link).
Relevant design and operating instructions
Note the following factors in the planning phase and during subsequent Quick
DC-Link operation:
the capacity of the charging circuits of the drive controllers that are
supplied with power
the sizes of the drive controllers and
their maximum output power.
Information
Note that you can only connect the 6th generation of STOBER drive
controllers.
Information
Quick DC-Link may be subject to system-specific or country-
specific standards.