Digital I/O and fieldbus items
9836 3123 01 335 (428)
Function button
(optional)
Controls a relay from fieldbus.
In I/O setup the selected relay
must be programmed to fieldbus
relay x. There are four different
items.
0 = Relay OFF
1 = Relay ON
Set fieldbus
relay x /Reset
fieldbus relay x
Tool starts tightening. The tool stops if the input signal disappears (equal to a start
with tool trigger).
The position of the tool direction ring is not taken into
account. This may cause tool reaction forces in a direction
unexpected to the operator.
Remote start is not available for Tensor STB tools.
Tool starts tightening if the input pulse is > 100 ms. Tool runs until target is reached.
The position of the tool direction ring is not taken into
account. This may cause tool reaction forces in a direction
unexpected to the operator.
Remote start is not available for Tensor STB tools.
Sends a scan request to ST
scanner. The scan LED on an
ST scanner is lit if a scan
request is configured for the
LED in ST scan configuration.
Scanner source must be correct.
Request ST Scan
/no signal
Resets all identifiers and relays
for identifier.
0 = Not used
1 = Reset all ID
Reset all
identifier
/no signal
Resets the batch counter to 0.
0 = Not used
1 = Reset the
batch
Reset bi-stable relay No. 1
Reset bi-stable relay No. 1
0 = Not used
1 = Reset Job
Status
Reset Job Status
/no signal