Digital I/O and fieldbus items
336 (428) 9836 3123 01
Description
Fieldbus items
Digital inputs
Name
Description
String
length
Data type
Value
Set signal
/Reset signal
Internal I/O
I/O Expander
ST GPIO
Function button
(optional)
Reset latest
Identifier
Resets the latest identified
identifier.
1 bit
0 = Not used
1 = Reset latest
Id
Reset latest
identifier
/no signal
X
X
X
X
Reset NOK
counter
Unlocks (if locked) and resets
Possible coherent not ok
tightening counter.
1 bit
0 = Not used
1 = Reset NOK
counter
Reset NOK
counter
/no signal
X
X
X
X
Reset relay
Resets all relays except
tracking event relay
1 bit
0 = Not used
1 = Reset
Reset relay /no
signal
X
X
X
Reset result status
Resets all result status on relay,
RE-Alarm and fieldbus.
1 bit
0 = Not Used
1 = Reset result
Reset result
status /no signal
Restart Job
Stops current Job and restarts
the same Job from 0.
1 bit
0 = Not used
1 = Restart Job
Restart Job /no
signal
X
X
X
X
Select next Pset
Selects next Pset.
1 bit
0 = Not used
1 = Select next
Pset
Select next Pset
/no signal
X
X
X
X
Select prev Pset
Selects previous Pset.
1 bit
0 = Not used
1 = Select
previous Pset
Select previous
Pset /no signal
X
X
X
X
Selector control
green light
Used to set green light on
selector when selector external
controlled is active. Two bits
for one position, 01 flash, 10
solid others off.
32 bits
OA
0=device ID
1=not used
2=position 1-4
3=position 5-8
Set selector
green light
/reset selector
green light
Selector control
red light
Used to set red light on selector
when selector external
controlled is active. Two bits
for one position, 01 flash, 10
solid others off.
32 bits
OA
0=device ID
1=not used
2=position 1-4
3=position 5-8
Set selector red
light
/reset selector
red light
Set batch size / Set
batch size Pset ID
Sets batch size in indicated Pset
ID (Set Batch Size Pset ID).
These two items must be used
together.
0<Batch Size<=99
2 - 8 bits in
the same
BF
00000000 = 0
11111111 = 255
Set batch size
and Pset id /no
signal
2 bytes
U16
Binary
representation
(Decimal 0-
65535)
Set bistab relay 1
Activate bi-stable relay No. 1
X
X
X
Set bistab relay 2
Activate bi-stable relay No. 2
X
X
X