Parameter list
9836 3123 01 345 (428)
Parameter
number
Parameter name
Description
Default
setup
P144
Cycle abort timer
If the tool does not reach its shut off point, this timer will shut it off. The
timer is activated when the tool trigger is pressed.
The value is adjustable between 0.1 and 60.0 seconds.
30 s
P150
Batch count
Activates a function that measures how many times a tightening is repeated.
It must be determined from where P151 Batch size value should be read, if
this parameter is activated.
Options:
Off: batch count functionality is not used.
Pset: use batch size of a Pset.
Fieldbus: an external source decides P151 Batch size via fieldbus.
Ethernet/serial: an external source decides P151 Batch size via Ethernet or
serial interface.
If batch count is used in a Job (that includes the specific Pset),
this parameter is recommended to be set to “Off”.
Off
P151
Batch size
The size can be 1 - 99. To set this parameter, the P150 Batch count must be in
active mode.
Batch size defined in Job overrides batch size defined in Pset.
1
P152
Lock at batch done
The tool will be locked when reaching Batch done. Batch done is reached
when the number of correct tightenings is equal to P151 Batch size.
No
P153
Max coherent
NOK’s
Defines the number of possible subsequent NOK (not OK) tightenings. This
parameter is overruled by M208. To be able to set a value for P153 the
parameter J301 Job type must be set to 'Forced' or 'Free and forced'
Range: 1-10.
0 (Off)
P160
High speed
rundown
High speed rundown is a function for reducing the cycle time by running the
tool at high speed during rundown.
High speed rundown is a stage inserted between Soft start and Step 1, i.e. the
Soft start time and Soft start speed affects the number of degrees of the
rundown phase. This gives the possibility for fast tightening cycles even for
long bolts with a small angle that require a slow step-one speed to avoid
overshoots.
Off
P161
Rundown speed
Rundown speed in percent.
100 %
P162
High speed interval
High speed rundown interval.
9999 deg
P163
High speed ramp
Defines the acceleration to P161 Rundown Speed during the high speed
rundown stage. The value is adjustable between 0 and 100 percent. A low
percentage gives fast acceleration.
10%
P164
Disable high speed
rundown speed once
if NOK
Disable the high speed rundown function after a NOK tightening
and enable high speed rundown speed when the tightening is OK. This
function is only possible to enable if the P160 is On
Off
P170
Adjustable limit
Adjustable positioning limit for open end tools. Used to set torque limit for
the positioning of the tool after tightening. If set to No the internal default
value is used as limit.
No

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals