Parameter list
9836 3123 01 359 (428)
Parameter
number
Parameter name
Description
Default
setup
J312
Decrement batch at
OK loosening
Yes/No/If last tightening OK
If YES, an OK Loosening generates a batch decrement for both OK and
NOK tightening. Set to If last tightening OK to decrement only for OK
tightening.
It is not possible to go back one step after the Job has been completed.
If ”batch counter type” is set to OK and last tightening was
a NOK tightening, an OK loosening will not decrease the
batch counter.
When the control strategy “Ds con” is implemented and
this parameter is set to “Yes”, the batch does not
decrement after an OK loosening.
No
J320
Max time to start
Job
This parameter defines the time limit, from when the Job is running to
when the first tightening is started or batch increment/bypass is performed.
If the time limit is exceeded the Job will be aborted. The timer restarts if a
Job is reselected.
Allowed values are between 1 - 9999 seconds. Value 0 (seconds)
deactivates this function.
0
J321
Max time to
complete Job
This parameter defines time limit, from Job is up running to the last
tightening in the Job is started. If the time limit is exceeded the Job will be
aborted.
Allowed values are between 1 - 9999 seconds. Value 0 (seconds)
deactivates this function.
0
J322
Display result at
auto select
This parameter is a timer for Jobs with auto selected Psets/Multistages. It
defines the time for tightening result to be displayed on a PF Graph or PF
Compact. The result disappears, and LED OK, NOK and nxOK shuts off,
when the tool trigger is pushed or if the time limit is exceeded.
The timer also works for restart Job, when a Job is completed, before
another Pset/Multistage is selected or when a Pset/Multistage is deselected.
Allowed values are between 1 - 60 seconds. Value 0 (seconds) deactivates
this function.
0
J330
Use line control
The Job will be ready to start when a Job with activated Line control has
been selected and the line control start signal has been received.
Otherwise, if line control start signal has not been received the Job will not
be ready to start and the tool will be locked until the line control start
signal is received.
A line control start signal is an external signal defined to be received by PF
from a digital input. This signal can be received before or after a Job
selection.
Line control start signal status will be cleared when the running Job has
been completed or aborted.
Line control related inputs/outputs have only an effect on a Job reference
and when this parameter is set to Yes.
No

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals