Event codes
402 (428) 9836 3123 01
Event
code
Event name
Description
Procedure
E340
Xucl tq
The last subgroup mean torque value is larger than the
upper control limit.
The statistic events give an
indication of irregularities in the
tightening process.
If needed:
Check the programming.
Check the tool status.
Check the tightening material and
joint components.
Check the work station set-up and
procedure.
E341
Xlcl tq
The last subgroup mean torque value is lower than the
lower control limit.
See E340 Xucl tq
E342
Rucl tq
The last subgroup range torque value is larger than the
upper control limit.
See E340 Xucl tq
E343
Rlcl tq
The last subgroup range torque value is lower than the
lower control limit.
See E340 Xucl tq
E344
Cp tq
The torque Cp is lower than 2.
See E340 Xucl tq
E345
Cpk tq
The torque Cpk is lower than 1.33.
See E340 Xucl tq
E346
7inc x tq
Trend deviation alarm, the subgroup torque mean value
has increased 7 times consecutively.
See E340 Xucl tq
E347
7dec x tq
Trend deviation alarm, the subgroup torque mean value
has decreased 7 times consecutively.
See E340 Xucl tq
E348
7inc r tq
Trend deviation alarm, the subgroup torque range value
has increased 7 times consecutively.
See E340 Xucl tq
E349
7dec r tq
Trend deviation alarm, the subgroup torque range value
has decreased 7 times consecutively.
See E340 Xucl tq
E350
7above x tq
Trend deviation alarm, the subgroup torque mean value
has been above the average mean value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E351
7below x tq
Trend deviation alarm, the subgroup torque mean value
has been below the average mean value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E352
7above r tq
Trend deviation alarm, the subgroup torque range value
has been above the average range value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals