Event codes
402 (428) 9836 3123 01
The last subgroup mean torque value is larger than the
upper control limit.
The statistic events give an
indication of irregularities in the
tightening process.
If needed:
Check the programming.
Check the tool status.
Check the tightening material and
joint components.
Check the work station set-up and
procedure.
The last subgroup mean torque value is lower than the
lower control limit.
The last subgroup range torque value is larger than the
upper control limit.
The last subgroup range torque value is lower than the
lower control limit.
The torque Cp is lower than 2.
The torque Cpk is lower than 1.33.
Trend deviation alarm, the subgroup torque mean value
has increased 7 times consecutively.
Trend deviation alarm, the subgroup torque mean value
has decreased 7 times consecutively.
Trend deviation alarm, the subgroup torque range value
has increased 7 times consecutively.
Trend deviation alarm, the subgroup torque range value
has decreased 7 times consecutively.
Trend deviation alarm, the subgroup torque mean value
has been above the average mean value of the average of
the latest ten subgroups 7 times consecutively.
Trend deviation alarm, the subgroup torque mean value
has been below the average mean value of the average of
the latest ten subgroups 7 times consecutively.
Trend deviation alarm, the subgroup torque range value
has been above the average range value of the average of
the latest ten subgroups 7 times consecutively.