Event codes
9836 3123 01 403 (428)
Event
code
Event name
Description
Procedure
E353
7below r tq
Trend deviation alarm, the subgroup torque range value
has been below the average range value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E354
2sigma x tq
Trend deviation alarm, the last subgroup torque average
is outside Xtq-bar-bar - 2 sigma.
See E340 Xucl tq
E355
2sigma r tq
Trend deviation alarm, the last subgroup torque range
average is outside Rtq-bar-bar - 2 sigma.
See E340 Xucl tq
E360
Xucl ang
The last subgroup mean angle value is larger than the
upper control limit.
See E340 Xucl tq
E361
Xlcl ang
The last subgroup mean angle value is lower than the
lower control limit.
See E340 Xucl tq
E362
Rucl ang
The last subgroup range angle value is larger than the
upper control limit.
See E340 Xucl tq
E363
Rlcl ang
The last subgroup range angle value is lower than the
lower control limit.
See E340 Xucl tq
E364
Cp ang
The angle Cp is lower than 2.
See E340 Xucl tq
E365
Cpk ang
The angle Cpk is lower than 1.33.
See E340 Xucl tq
E366
7inc x ang
Trend deviation alarm, the subgroup angle mean value
has increased 7 times consecutively.
See E340 Xucl tq
E367
7dec x ang
Trend deviation alarm, the subgroup angle mean value
has decreased 7 times consecutively.
See E340 Xucl tq
E368
7inc r ang
Trend deviation alarm, the subgroup angle range value
has increased 7 times consecutively.
See E340 Xucl tq
E369
7dec r ang
Trend deviation alarm, the subgroup angle range value
has decreased 7 times consecutively.
See E340 Xucl tq
E370
7above x ang
Trend deviation alarm, the subgroup angle mean value
has been above the average mean value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E371
7below x ang
Trend deviation alarm, the subgroup angle mean value
has been below the average mean value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E372
7above r ang
Trend deviation alarm, the subgroup angle range value
has been above the average range value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals