Event codes
404 (428) 9836 3123 01
Event
code
Event name
Description
Procedure
E373
7below r ang
Trend deviation alarm, the subgroup angle range value
has been below the average range value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E374
2sigma x ang
Trend deviation alarm, the last subgroup angle average is
outside Xang-bar-bar-2 sigma.
See E340 Xucl tq
E375
2sigma r ang
Trend deviation alarm, the last subgroup angle range
average is outside Rang-bar-bar-2 sigma.
See E340 Xucl tq
E380
Xucl cm
The last subgroup mean CM value is larger than the
upper control limit.
See E340 Xucl tq
E381
Xlcl cm
The last subgroup mean CM value is lower than the lower
control limit.
See E340 Xucl tq
E382
Rucl cm
The last subgroup range CM value is larger than the
upper control limit.
See E340 Xucl tq
E383
Rlcl cm
The last subgroup range CM value is lower than the
lower control limit.
See E340 Xucl tq
E384
Cp cm
The CM Cp is lower than 2.
See E340 Xucl tq
E385
Cpk cm
The CM Cpk is lower than 1.33.
See E340 Xucl tq
E386
7inc x cm
Trend deviation alarm, the subgroup CM mean value has
increased 7 times consecutively.
See E340 Xucl tq
E387
7dec x cm
Trend deviation alarm, the subgroup CM mean value has
decreased 7 times consecutively.
See E340 Xucl tq
E388
7inc r cm
Trend deviation alarm, the subgroup CM range value has
increased 7 times consecutively.
See E340 Xucl tq
E389
7dec r cm
Trend deviation alarm, the subgroup torque range value
has decreased 7 times consecutively.
See E340 Xucl tq
E390
7above x cm
Trend deviation alarm, the subgroup CM mean value has
been above the average mean value of the average of the
latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E391
7below x cm
Trend deviation alarm, the subgroup torque mean value
has been below the average mean value of the average of
the latest ten subgroups 7 times consecutively.
See E340 Xucl tq
E392
7above r cm
Trend deviation alarm, the subgroup CM range value has
been above the average range value of the average of the
latest ten subgroups 7 times consecutively.
See E340 Xucl tq

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals