Appendix B. Status, Settings, and Data Table Information (Status/Settings/DTI)
PakBusTCPEnabled
Settings Editor: ???
Keyboard: Settings (TCP/IP) ≈ line 39
Aliased from: ServicesEnabled()
CRBasic: variable = settings.keyword;
SetSettings()
Enables (True) or disables (False) the PakBus TCP
service.
read/write
BOOLEAN
True True or False
PakBusTCPPassword
Settings Editor: PakBus/TCP Password
Keyboard: Settings (General) ≈ line 10
CRBasic: variable = settings.keyword;
SetSettings()
When active (not blank), a log-in process using an
MD5 digest of a random number and this password
must take place successfully before PakBus
communications can proceed over an IP socket.
read/write
STRING
none
(inactive)
0 to 63
characters
PanelTemp
Station Status: Panel Temperature
Keyboard: Status Table ≈ line 15
CRBasic: variable = status.keyword
Current wiring-panel temperature. Measurement is
made in background calibration.
read only
FLOAT
°C
n/a
-40 to 85
PingEnabled
Settings Editor: Ping Enabled
Keyboard: Settings (TCP/IP) ≈ line 38
CRBasic: variable = settings.keyword;
SetSettings()
Enables (True) or disables (False) the ICMP ping
service. Replaces old ServicesEnabled().
read/write
BOOLEAN
True
True or False
PortConfig()
Keyboard: Status Table ≈ line 51
CRBasic: variable = status.keyword
Configuration of C terminals. Array elements in
numeric order of C terminals.
read only
STRING
array
Input
Input,
Output,
SDM, SDI-
12, Tx, Rx
PortStatus()
Keyboard: Status Table ≈ line 50
CRBasic: variable = status.keyword
States of C terminals configured for control.
On/high (True) or off/low (False). Array elements
in numeric order of C terminals. Updated every 500
ms.
read/write
BOOLEAN
array
False
True or False
pppDial
Settings Editor: PPP Dial
Keyboard: Settings (TCP/IP) ≈ line 28
CRBasic: variable = settings.keyword;
SetSettings()
Specifies the dial string that follows ATD (e.g., #777
for Redwing CDMA) or a list of AT commands
separated by ';' (e.g., ATV1;
AT+CGATT=0;ATD*99***1#), that are used to
initialize and dial through a modem before a PPP
connection is attempted. A blank string means that
dialing is not necessary before a PPP connection is
established. CRBasic program will recompile if
changed from NULL to not NULL, or from not
NULL to NULL.
read/write
STRING
none n/a
624

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4