SV-ADAHRS-200 Module Installation and Configuration
7-12 SkyView HDX System Installation Manual - Revision E
• Keep aircraft still (do not move) when pressure is applied.
Steps:
1. The aircraft itself should be temperature stable. For example, if the aircraft is
moved from outside in the sun to a hangar for testing, tests should not be started
until the airplane has stabilized at the hangar temperature.
2. Turn SkyView on and let it warm up until the altitude reading is stabilized. This
period should be at least 5 minutes, but may take longer depending on
environmental conditions.
3. Turn SkyView off.
4. While SkyView is off, apply the pressure required by your test to pitot and/or static
port via your test equipment.
5. Turn on SkyView (external or internal battery power is acceptable). Keep aircraft
still while SkyView is powered on. Do not adjust the pitot or static pressures being
applied to the ADAHRS while it is powered on.
6. Verify airspeed and/or altitude reading.
7. Turn SkyView off (using button 1 is a good option for this operation).
8. Repeat steps 4-7 for each required pressure point in the test.
See related procedure:
SV-XPNDR-261 Transponder Installation and Configuration, Performing Transponder
Checks.