Appendix A: Maintenance and Troubleshooting
23-4 SkyView HDX System Installation Manual - Revision E
23.6 Returning SkyView Components to Service after Repair
SkyView Network enabled components such as modules and servos are shipped in a
“like new” state after repair. To return a SkyView Network component to SkyView
Network, follow the following directions. Note that there are three (3) different procedures
for returning SkyView displays to service, depending on how the display is returned:
23.6.1 SkyView Display Scenario 1
When the documentation furnished with the repaired display indicates that is being
returned to you with the exact same settings/configuration as it was sent to Dynon
Avionics with
1. In this case, the display contains EXACTLY the same configuration as it did when
you sent it in. If your system was working properly before the display failed and
was sent in for repair:
a. Reinstall the display, reconnecting all harnesses and connections as originally
installed.
2. Power up the entire SkyView System (all displays, modules, servos, etc.)
3. If this is the only display installed:
a. Reconfigure SkyView Network under SETUP MENU > SYSTEM SETUP >
SKYVIEW NETWORK SETUP > CONFIGURE…
b. Confirm all SkyView Network components are found, including ALL displays
that are in the aircraft.
4. If there is another display installed in the aircraft:
a. Using a display that never left the aircraft (and is presumably configured and
working correctly):
i. Reconfigure SkyView Network under SETUP MENU > SYSTEM SETUP >
SKYVIEW NETWORK SETUP > CONFIGURE…
ii. Confirm all SkyView Network components are found.
5. Confirm that all settings, behavior, and configuration are normal.
6. If your SkyView system is not working normally, contact Dynon Avionics Technical
Support (contact information at the beginning of this manual) for further assistance.
23.6.2 SkyView Display Scenario 2
When repaired display is the ONLY display in the aircraft, and the documentation
furnished with the repaired unit indicates that the display was shipped “like new:”
1. Reinstall the display, reconnecting all harnesses and connections as originally
installed.
2. Power up the entire SkyView System (all displays, modules, servos, etc.).
3. If you have an EXPORT SETTINGS file on a USB flash drive: